I am in the process of buttoning up a Nitehawk conversion on my Voron. I also replaced my extruder thermistor with an OE replacement purchased from a reputable vendor.

Post setup, my heated bed is reading spot on (it’s 18.3 C in my basement aka 65 F). I verified that my extruder is also at ambient temperature by wedging a Thermapen under its silicone sock and letting it acclimate for 10 minutes. The I’m not sure why the extruder would be reading high.

I bought a spare thermistor and wired it in. The result was identical.

Thoughts? Ideas? I’m pretty sure I have the Nitehawk and thermistor set up correctly.

[extruder] step_pin: nhk:gpio23 dir_pin: nhk:gpio24
enable_pin: !nhk:gpio25
heater_pin: nhk:gpio9
sensor_pin: nhk:gpio29
pullup_resistor: 2200
sensor_type: ATC Semitec 104NT-4-R025H42G`

  • IMALlama@lemmy.worldOP
    link
    fedilink
    English
    arrow-up
    1
    ·
    2 days ago

    Huh, thanks for the additional info. On the hot side the reported temperature seems to be spot on so I’m not going to worry about cold temps being off.